📜 ⬆️ ⬇️

Excel-calculator of complex wave resistance transformation on waveguide line segments

In calculations in the high-frequency technique, two types of problems often arise:



For an instant and convenient solution, with the presentation of the result in tabular and graphical form, we will create a tool.


image


In the diagram, Za is a source device that has known wave properties.
Z0 - segment of the waveguide line of length L and wave impedance (characteristic impedance) Z0 (Ohm)


For the particular case when Za is purely active (tuned to an antenna, or an electronic device whose reactivity is removed using all kinds of LC shunts), the resulting resistance Zin is calculated according to the well-known telegraph equation:
image


In the case when K is a multiple of ¼ λ, such a segment does not add reactivity, but only transforms one real resistance into another. If K is a multiple of ½ λ - the line does not make any changes at all, regardless of whether it is consistent or not.


Such private properties are very widely known and very widely used:



Working with this formula has 2 practical limitations:



Therefore, to work with complex resistance (with a source having reactivity), it is necessary to return to the less well-known initial formula:


image


For the particular case when the imaginary part ZL = 0, the previous formula with tangents was derived from it.


The cosine and sine in this formula are hyperbolic.
Cosine and sine are taken from the propagation constant (γ), this is a complex number, the real part consists of the attenuation constant α (in Napier per unit length, where Napier is an analog of decibels, only with a logarithm not on a decimal basis, but a natural number e) and phase constant ß (the number of radians fitting in the wavelength).
In the general case, for arbitrary long lines, calculating γ is not an easy task, it requires knowing all 4 primary parameters of the transmission line : R, L, C, and G.
But in the particular case if the line is lossless, i.e. The following conditions are met:



The dimension of the units L, γ and λ is any (meters, feet, millimeters), the main thing is that all three units be in the same dimension. In the calculator we will use millimeters.


In the precomputer era, working with such a formula was almost impossible, so engineers used the Wolpert-Smith diagram


image


Working with it is very laborious, especially in a wide frequency band.


Using the fact that MS Excel fully supports complex numbers and operations on them, we will create a calculator. Since Google Docs does not support the sine / cosine function from a complex number (IMCOSH, IMSINH, etc.); in the M | N columns, we replace these functions with their component parts. In the offline version of Excel / OpenOffice, you can use the direct function.


The quality of matching is usually evaluated by the resultant CWS, so we immediately add to the calculator its calculation through the reflection coefficient Γ (Greek gamma, you can often find a record through ρ)


image


As a teaching example, let's take the popular Digital-9 patch antenna for receiving television broadcasting in the UHF range 470-800 MHz.


Own characteristic impedance of the antenna, without a transforming segment, is shown on the graph:


image


In a wide frequency band, the antenna impedance varies within very wide limits: the reactivity is always positive (inductive) with a minimum near 530 MHz (almost resonance) and reaches 200-350 Ohm in the frequency band. Radiation resistance ranges from 200 to 600 ohms.


https://goo.gl/w8z9U2 (Google Docs)


So actually the calculator. We enter the incoming data in the yellow cells, the values ​​that need to be manually selected - in turquoise. Green columns — output impedance; lilac — SWR values ​​for reference.


Selecting the length and resistance - we get an instant report on the CWS in the entire frequency band. If desired, you can add a schedule of the CWS.


For example, if the line has a length of 155 mm and Z0 = 170 Ohm, then we get the following curve of the CWS on the load of 75 Ohms:


image


Input data for yellow cells may be:



Using the calculator you can calculate multi-stage transformers from several segments connected in series. To do this, it is necessary to create a duplicate of “Sheet” in Excel, enter the links to the green cells from the previous sheet in the yellow column. Or you can place the data on one "Sheet" - adding new lines in which to specify the links to the previous lines as incoming cells. But in the latter case, it is necessary to create several Zo / L cells (for each cascade) and tweak in the formulas references to Zo / L for the desired cascade.


If the data source is CAD-modeling, then the answer can be obtained simply by simulating a segment of the transformer in the model. But the calculation of such models using the finite element method (HFSS, CST) takes a lot of time, especially in a wide frequency band. Excel calculator gives an instant answer and allows you to see the trend and sensitivity, therefore, it is more convenient for a rough calculation.


For cases where the line will be made of materials with attenuation:



To calculate the impedance in long lines with attenuation (coaxial cables, twisted pairs), you can use the Excel calculator: https://ac6la.com/tlmath.html


Checking the correctness of the model and calculator for errors


Since The calculator model is comparatively complex, one can make a methodological error in it or in a formula — it needs to be checked.
Since we obtained the initial data for the training example from Ansys HFSS, we can draw the transformer calculated using Excel into the HFSS model and calculate the characteristic impedance at the end of the line using HFSS.
For example, take the line length of 152 mm and Zo = 140 ohms.
In the model, we used a tap from a patch of 4x0.5 mm.
Using well-known analytical equations, we calculate that the distance between the 4x0.5 mm band and the endless earth screen should be 6.0 mm for Zo = 140 Ω.
Extend the existing strip to a length of 152 mm at a height of 6 mm from the reflector and assign a port to the end of the line.
Compare the predicted Re / Im with the results of the HFSS simulation.
image


The values ​​and trends coincide quite accurately, so the calculator can be trusted.
Minor discrepancies are explained by small changes in the geometry of the model - fitting the point of connecting the supply strip to the height of the installation of the transformer segment (measured at a height of 4.0 mm, and the transformer was chosen to a height of 6.0 mm), bending and connecting the port at the end of the transformer.


')

Source: https://habr.com/ru/post/352852/


All Articles