FlexPod Express: UCS-Managed Configuration

Among the three previous Small / Medium / Large configurations in FlexPod Express, another one appeared under the name Cisco UCS-Managed . This article will discuss this new configuration. FlexPod Express and FlexPod Datacenter are divided into two main types of connection: direct connection of storage to servers (there is no switch between storage and servers) or through switch (there is a switch between storage and servers), I remind you that Fabric Interconnect is not a switch, but part of the UCS server domain .

It is worth noting several important differences of the new configuration from the previous three.


Redundant switches
9.3 Cisco Nexus Switches
Redundant switches are required for all FlexPod Express architectures.
The Cisco Nexus 3048 GbE switches. FlexPod Express large architectures are built using the Cisco Nexus 3524 10GbE switches or the Cisco Nexus 9396 10GbE switches. FlexPod Express with Cisco UCS Mini (Cisco UCS-managed) architecture is validated using the Cisco Nexus 3524. This configuration can also be deployed with a standard switch.

www.netapp.com/us/media/tr-4293.pdf


It is important to note that the absence of Nexus is provided only in the FlexPod Express configuration with direct connection of the storage to UCS mini . Nexus switches are still needed for FlexPod DataCenter , even in the case of Storage Directly Attached configurations , as well as FlexPod Express Small / Medium / Large and FlexPod Express UCS-managed (where you need a switch between FI and DSS). Direct connection for both FlexPod DataCenter and FlexPod Express is supported with block protocols only.
')

Minimum requirements for software:


NetApp Data ONTAP

Cisco

All software versions must be checked in the compatibility matrix .

Support level requirements




If you already have NetApp and UCS Mini



You can register them as FlexPod Express and get cooperative technical support. Similarly, you can register and FlexPod DataCenter. For this you need to meet a number of requirements:

When all requirements are met, you should contact your partner (integrator) with a request to register your existing configuration as FlexPod Express / DataCenter. Integrator contact your NetApp distributor and representative who register such a system for cooperative support.

UCS Director



UCS Director is an orchestrator that can manage NetApp hardware, Nexus switches (including virtual and VM-FEX), manage server profiles, and virtual machines on various hypervisors. The orchestrator allows you to create workflows of previously created configuration sequences for the entire data center, automating and simplifying the process of its operation. UCS Director also contains a self-service portal, which makes it possible to provide IaaS and PaaS services for both internal and external consumption. It is also very important that the orchestrator allows billing of consumed resources, this makes it possible for IT departments to more easily justify their spending and attract additional investments in the IT budget.

The benefits of FlexPod configurations are here.

findings


Configurations of FlexPod architecture allow you to reduce the time for testing and commissioning solutions, as well as simplify operation in the future due to the openness of documentation and automation of routine administrative processes.

FlexPod with Cisco UCS Mini Design Guide

I ask to send messages on errors in the text to the LAN .
Comments, additions and questions on the article on the contrary, please in the comments .